LED operating light main feature


LED surgery shadowless light is widely used in hospital, the main function is to illuminate the surgical field to optimally observe small, low-contrast objects at different depths in the incision and body control. Since the operator's head, hands, and instruments may cause shadows on the surgical field, the operating light should be designed to minimize shadows and minimize color distortion. In addition, it must be able to continue working for a long time without emitting excessive heat, because overheating can make the patient uncomfortable, it will also dry the tissue in the surgical field, which is not conducive to the patient's recovery. Shandong Mingtai company glad to introduce mobile operation lamp advantage to you.
With the features of energy saving, environmental protection, safety, long life, low power consumption, low heat, high brightness, waterproof, miniature, shockproof, easy dimming, concentrated beam, easy maintenance; The working voltage is very low and the working current is small; Good impact and shock resistance, high reliability and long life; The intensity of the luminescence can be easily modulated by modulate the intensity of current strength. These are the excellent features of LED shadowless lamps, which perfectly improve the success rate of surgery and safety.





2018年9月12日星期三

How important is the shadowless light for surgery?


Firstly, surgery shadowless light is lighting equipment which us widely used in hospital, it is necessary lighting equipment for modern operating room. It is suitable for different surgeries, such as brain surgery and thoracic surgery.
Secondly, why does surgery need LED operation light? Everybody knows that the light source illumination in our daily life will show a shadow, it doesn’t have big effect on our lives. But if we use ordinary light in surgery, the shadow of the medical staff will be presented, maybe the surgery field will be blocked, which will affect surgery.
Thirdly, LED medical light is not only without shadow. To meet the surgery requirement, shadowless lamp is not only required to eliminate shadows as much as possible, reduce the distortion of color, but also maintain long-term work. Some operations require more than ten hours of continuous work, if the situation is urgent, the surgical shadowless lamp must be able to work continuously for dozens of hours or even hundreds of hours.
Finally, ordinary light will emite excessive heat, which will boring the tissue in surgery field, affect surgery, and also affect the patient's body.
In summary, LED shadowless lamp can better see the objects of different depths and low contrast in the incision and body control. It is helpful to patient, and bring great convenience to medical staff.


2018年9月3日星期一

How to extend the life of shadowless lamps?


If you do not check and maintain the equipment after the surgery shadowless light is bought, it will cause frequent failures, makes its life greatly reduced. So how to extend the life of LED shadowless lamp?
1. Periodic inspection, once a year. Check the connection status of each connection part of the LED medical light, prevent accidents caused by loose parts. After the operation is completed, the power must be turned off
2. To change the fuse, you must turn off the power. Replace the fuse of the same model. When changing the lamp bulb, you must first cut off the power supply and wait until the lamp bulb has cooled before replacing it. When the filter glass is damaged, the factory should be promptly repaired, otherwise it may cause burns of the body tissue.
3. Replace the lamp bulb, first cut off the power, then remove the disinfection handle, and then use a screwdriver to remove the light source system. The damaged bulb can only be replaced after it has been determined that the lamp has cooled down.
Note: Do not handle the bulb directly with your hand to avoid fingerprints on the new bulb and affect the light source.
4. Before the operation, the disinfection handle should be removed and disinfected with 75% alcohol solution. Wipe the lamp head with a soft cloth dampened with 75% alcohol.
Note: LED operation light handles, disinfection handles, and light panels must not be scrubbed with organic solvents.
5. Balance adjustment. First remove the plastic cover of the balancer which is near the lamp end and find the round nut inside the balancer tube. Adjusting the up and down movement force of the lamp head with a special adjustment lever, so that the movement force of the lamp head up and down is basically the same.
6. Damping adjustment. Adjustment of the rotational damping of the lamp body around the main shaft, using a flat-blade screwdriver to adjust, clockwise rotation.